Eurocode applied. g. Applicable for the design of structures that remain in the elastic range, seismic isolation systems, and calculation of seismic displacements. Second moment of the area of gross cross-section: I = 0. All of the EN Eurocodes relating to materials have a Part 1-1 which covers the design of buildings and other civil engineering structures and a Part 1-2 for fire design. The European Standard EN 10365 has superseded the following older standards: Geometry of IPE profiles: Euronorm 19 Jul 12, 2022 · EN 1997 Eurocode 7 shall be applied to the geotechnical aspects OF the design of buildings and other civil engineering works and shall be used in conjunction with EN 1990:2002 that establishes the principles and requirements for safety and serviceability, describes the basis of design and verification and gives guidelines for related aspects of structural reliability Parts EN 1997-1:2004 Jan 1, 1992 · Eurocode 2. Jan 1, 1992 · I-shaped, T-shaped and box-shaped reinforced concrete cross-section - Calculation of required reinf. e. Jan 4, 1991 · Eurocode 1 Wind load on flat roofs (external and internal pressure coefficients) Description: Calculation of wind load action effects on flat roofs (including small parapets). 00, units = mm) Profile dimensions. The net effect of the wind pressure on the upper and lower surface for zones A, B, C on the roof surface are Policies & Standards. 4) as: KPE = p12 / ( p2 ⋅ p32) = 0. 5. Summary: Calculations for Eurocode 3: Steel material properties, design properties of IPE, HEA, HEB, HEM, CHS (tube) profiles, ULS design of steel member, elastic critical moment Mcr. 00, units = mm) The design resistances of the profiles correspond to cross-section resistances reduced by the partial material factor γM0 in accordance with EN1993-1-1 §6. Preliminary SDOF analysis of seismic isolation. Wind load on prismatic elements with rectangular cross-section (force coefficient) Description: Calculation of wind load action effects on prismatic elements with rectangular cross-section. 4. Jan 1, 1992 · ULS design of rectangular reinforced concrete cross-section for bending and axial force (calculation of required reinforcement for given bending moment / axial force, maximum moment resistance MRd for given axial force, or complete M-N interaction diagram for given reinforcement layout) e. 3 (2) the following modifications are applicable for the value of the concrete modulus of elasticity Ecm: a) for limestone aggregates the value should be reduced by 10%, b) for sandstone aggregates the value should be reduced by 30%, c Jan 1, 1993 · Eurocode 3 ULS Design of steel member (beam/column) with doubly-symmetric flanged cross-section (IPE, HEA HEB, HEM, UB, UC, UBP or custom) Description: Ultimate Limit State design of uniform steel member (beam/column) with I-section or H-section (IPE, HEA HEB, HEM, UB, UC, UBP or custom) according to EN1993-1-1 for axial force N, shear force V, bending moment M, flexural buckling, lateral . The standards for concrete, steel, composite steel and concrete, and timber Jan 1, 1992 · Calculation of shear reinforcement and verification of concrete strength for general concrete cross-section (rectangular, T-beam, I-beam) according to Eurocode 2 (EN1992-1-1) I IΙ IΙ I Eurocode 1 ( EN1991 ) Jan 1, 1992 · Calculation of concrete creep coefficient and shrinkage strain. Inertia properties about minor axis z-z. 3 (2), §6. ULS Design of steel member (beam/column) with hollow circular cross-section (CHS or custom tube) Ultimate Limit State design of uniform steel member (beam/column) with hollow circular section (CHS or custom tube) according to EN1993-1-1 for axial force N, shear force V, bending moment M, torsional moment T, flexural buckling, and Over the last 20 years, methodologies inherent to existing structures have evolved in many countries and applied on a national level. Altitude correction may also be specified in the National Annex for EN1991-1-4 §4. The directional and season factors are Eurocode 3. o the design of bridges and water retaining structures in Parts 2 and 3 (whose clauses work by exception to Part -1-1). For distributed reinforcement bars at spacing s the total weight is: wtot / s = ρ ⋅ As / s. The spreadsheets that we call the applications on this website allow an online calculation of parameters following the Eurocodes. , SLS bending moment resistance, or M-N interaction diagram for given reinforcement layout according to Eurocode 2 (EN1992-1-1) The Concrete Design add-on for RFEM 6 / RSTAB 9 provides you with the option to design reinforced concrete members, columns, and surfaces (RFEM) according to Eurocode. Simple analytical equations based on the convolution equation are presented. New European technical rules will be developed to cover the assessment, re-use and retrofitting of existing structures, in keeping with the principles and fundamental requirements of the EN Eurocodes. A set of calculation tools is provided that correspond to application of particular sections of the structural Eurocodes (EN1990 to EN1999) and the corresponding Jan 8, 1993 · Design aid - Table of design properties for individual metric hexagonal bolts including stress area, yield strength, ultimate strength, shear resistance, tensile resistance, interaction between shear and tension, bearing resistance, punching shear resistance. Concrete nominal cover and minimum concrete class for durability (reinforcement bars and prestressing tendons) Description: Calculation of required nominal concrete cover cnom for reinforcement steel and prestressing steel. Reinforcement layers of the flanges can be concentrated at the centerline of the corresponding flange as an approximation. The elastic displacement response spectrum SDe ( T) is obtained by direct transformation of the elastic acceleration response spectrum Se ( T) according to the fundamental relation of structural dynamics, as specified in EN1998-1 §3. www. See EN1992-1-1, §3. com. According to: EN 1992-1-1:2004+AC2:2010 Section 7. Jan 4, 1991 · Eurocode 1. 5 kN/m 3 . Description: Calculation of the elastic response spectrum in terms of spectral acceleration and spectral displacement representing the seismic action in the horizontal or vertical direction. 8 fyk for the characteristic SLS combination. Jan 1, 1993 · Eurocode 3. eurocodeapplied. The net effect of the wind pressure on the upper and lower surface for zones A, B, C on the roof surface are Jan 1, 1992 · Calculation of shear reinforcement and verification of concrete strength for general concrete cross-section (rectangular, T-beam, I-beam) according to Eurocode 2 (EN1992-1-1) I IΙ IΙ I Eurocode 1 ( EN1991 ) Jan 4, 1991 · Eurocode 1. The aforementioned design Eurocode 1 Wind load on building side walls (external and internal pressure coefficients) Description: Calculation of wind load action effects on vertical side walls of building. Eurocode 2 gives specific rules dealing with: o the detailing of beams, slabs, flat slabs, columns, walls, deep beams, foundations, tying systems and o the design of precast, lightweight and plain concrete. 30 MPa for concrete class C30/37. 2 (5) tensile stress in the reinforcement should be limited to 0. com is a free online service that civil engineers can use to perform structural design calculations according to the latest Eurocodes. Calculation of elastic critical moment for lateral-torsional buckling of doubly-symmetric flanged cross-section (IPE, HEA HEB, HEM or custom) Calculation of elastic critical moment Mcr for lateral-torsional buckling of a uniform steel member with I-section or H-section (IPE, HEA HEB, HEM or custom) according to elastic buckling theory. The EN Eurocodes are a series of 10 European Standards, EN 1990 - EN 1999, providing a common approach for the design of buildings and other civil engineering works and construction products. Jan 1, 1993 · Eurocode 3 ULS Design of steel member (beam/column) with doubly-symmetric flanged cross-section (IPE, HEA HEB, HEM, UB, UC, UBP or custom) Description: Ultimate Limit State design of uniform steel member (beam/column) with I-section or H-section (IPE, HEA HEB, HEM, UB, UC, UBP or custom) according to EN1993-1-1 for axial force N, shear force V, bending moment M, flexural buckling, lateral Jan 4, 1991 · Eurocode 1 Wind load on free-standing walls and parapets (net pressure coefficients) Description: Calculation of wind load action effects on free-standing walls and parapets. Where Act is the area of concrete in tension just before formation of the first crack. For ULS verifications the partial load factor γ Q = 1. The directional and season factors are Eurocode 8 Elastic acceleration and displacement response spectra (for design of structures in the elastic range and calculation of displacements) Description: Calculation of the elastic response spectrum in terms of spectral acceleration and spectral displacement representing the seismic action in the horizontal or vertical direction. For typical steel profiles (IPE, HEA, HEB, HEM, UB, UC, UBP) the geometric properties of the cross-section are defined in the following standard: EN 10365 - Hot rolled steel channels, I and H sections - Dimensions and masses. 439 likes. 000 m 2 / 2. According to EN1993-1-1 §3. 3 : Fw = cscd ⋅ cf ⋅ Aref ⋅ qp ( ze ) where Aref = 106. 4(4) Jan 1, 1992 · EN 1992-1-1:2004+AC2:2010 Section 6. The Second Generation EN Eurocode parts will be Jan 4, 1991 · Eurocode 1 Wind load on free-standing walls and parapets (net pressure coefficients) Description: Calculation of wind load action effects on free-standing walls and parapets. For reinforced concrete elements where crack control is required the minimum amount of bonded longitudinal reinforcement is given in EN 1992-1-1 §7. 6 (1) as: cf = cf,0 ⋅ ψr ⋅ ψλ. Each application is composed of a title, a Jan 1, 1993 · For typical steel profiles (IPE, HEA, HEB, HEM, UB, UC, UBP) the geometric properties of the cross-section are defined in the following standard: EN 10365 - Hot rolled steel channels, I and H sections - Dimensions and masses. These documents, called Eurocodes, are systematically based on recently developed Council Directive 89/106/EEC “The Construction Products Directive” and its Interpretative Documents ID1 and ID2. In addition to the general ultimate limit state and serviceability limit state design checks, you can also perform stability analysis of the columns according to EC 2. 248505 m 4. Design values of additional material mechanical properties for structural steel. Implementation of Eurocodes in each Member State is a demanding task as each country has its own long-term tradition in design and construction. The total horizontal wind force is calculated from the force coefficient corresponding to the overall effect of the wind action on the cylindrical structure or cylindrical isolated element. Ultimate Limit State design of uniform steel member (beam/column) with I-section or H-section (IPE, HEA HEB, HEM, UB, UC, UBP or custom) according to EN1993-1-1 for axial force N, shear force V, bending moment M, flexural buckling, lateral torsional buckling, and interaction effects. Applicable for: Rectangular concrete cross-sections or webs of general concrete cross-sections (T-beam, I-beam, box-shaped). 1(1) for intermediate loaded areas A between 1m 2 and 10m 2 the external pressure coefficient c pe may be calculated between the values c pe,1 Eurocodes used by EU non-members or states in process of adoption. Jan 4, 1991 · Calculation of wind load action effects on duopitch roofs (external and internal pressure coefficients) for zones F, G, H, I, J according to Eurocode 1 (EN1991-1-4) Oct 12, 2010 · Eurocode 3. The dynamic earth pressure coefficient for passive state is calculated according to EN1998-5 equation (E. The value of γM2 must be provided manually when different than 1. Jan 1, 1992 · ULS design of circular or tubular reinforced concrete cross-section for bending and axial force (calculation of required reinforcement for given bending moment / axial force, maximum moment resistance MRd for given axial force, or complete M-N interaction diagram for given reinforcement layout) e. Jan 4, 1991 · The basic wind velocity is given as v b = v b,0 ⋅c dir ⋅c season where the fundamental value of basic wind velocity v b,0 is defined in EN1991-1-4 §4. 6035 2) = 2. Applicable for the design of ductile structures where the inelastic behavior is taken into account explicitly with the behavior factor q. 418 m 2 is the reference wind area for each sloped face of the canopy roof as calculated above. The final value at infinite time is calculated as well as the development curves as a function of time. 600. Inertia properties about major axis y-y. Jan 4, 1991 · The basic wind velocity is given as vb = vb,0 ⋅ cdir ⋅ cseason where the fundamental value of basic wind velocity vb,0 is defined in EN1991-1-4 §4. Torsional properties. 2 and §5. 6, the design values of the material properties and coefficients for structural steel are: Modulus of elasticity (Young's modulus): E = 210000 MPa. 2 (2) to avoid longitudinal cracks the compressive stress in the concrete should be limited to 0. 4, Annex E. , random, load combination and single load pairs. Calculation according to UK National Annex and Irish National Annex. For the case of lapped bars permanently in compression one bar of the transverse reinforcement should be placed outside each end of the lap length and within 4 Φ of the end. Jan 4, 1991 · Appropriate load factors should be applied for the relevant design situation. A lower value may be needed to satisfy the crack control requirements for the relevant combination (typically SLS quasi-permanent) e. Eurocode 8 Elastic acceleration and displacement response spectra (for design of structures in the elastic range and calculation of displacements) Description: Calculation of the elastic response spectrum in terms of spectral acceleration and spectral displacement representing the seismic action in the horizontal or vertical direction. 3. Jan 4, 1991 · The force coefficient cf for prism elements with rectangular cross-section is given in EN1991-1-4 §7. Jan 1, 1993 · EN1993: Design of Steel Structures. ULS Design of steel member (beam/column) with hollow rectangular or hollow square cross-section (RHS, SHS or custom) Ultimate Limit State design of uniform steel member (beam/column) with hollow rectangular section or hollow square section (RHS, SHS or custom) according to EN1993-1-1 for axial force N, shear force V, bending moment Jan 1, 1992 · The values of the reinforcement areas, reinforcement ratios and axial resistances of the cross-section correspond to the final reinforcement if different than the initially specified reinforcement. Applicable for: Uniaxial bending. These parameters are often required for several stages of a project: gathering of design basis, implementing a finite element model, or calculating structural resistances. According to EN 1992-1-1 §7. According to: EN 1992-1-1:2004+AC2:2010 Section 4. 2 : As,min = kc ⋅ k ⋅ fct,eff ⋅ Act / σs. Wind load on circular cylinders (force coefficient) Calculation of wind load action effects on circular cylinder elements. Jan 1, 1992 · Concrete Design Properties according to EN1992-1-1 ( γc = 1. The total horizontal wind force is calculated from the force coefficient corresponding to the overall effect of the wind action on the structure. 2(1)P and its value is provided in the National Annex. Calculation of required shear connection reinforcement and verification of concrete strength at the interface between concrete cast at different times. Eurocode 8. A value of δ = 0 is a typical reasonably conservative assumption. Jan 1, 1992 · The required transverse reinforcement should be placed at the outer thirds of the lap length l0, i. They are the recommended reference for technical specifications in public contracts. 000 m. External diameter of cross-section. The wind action on the structure (forces and pressures) can be derived from the peak velocity pressure. 2 (1) . Wind load on monopitch canopies (net pressure coefficients and overall force coefficient) Calculation of wind load action effects on monopitch canopies (i. EN 1990 establishes the principles and requirements for safety, serviceability and durability of structures designed to Eurocodes and should be applied whenever Eurocodes 1 to 9 (EN 1991 to EN 1999) are used for the structural design or appraisal of buildings and other civil engineering works. Values less than 90° correspond to wall back surface inclining forward. All Eurocodes. Jan 4, 1991 · Calculation of wind load action effects on flat roofs (external and internal pressure coefficients) for zones F, G, H, I according to Eurocode 1 (EN1991-1-4) Eurocode 8. 4 (2), §6. Therefore: ze = h = 5. Jan 1, 1992 · Description: SLS design of I-shaped, T-shaped, and box-shaped reinforced concrete cross-section for crack control (calculation of required reinforcement for given bending moment / axial force, direct calculation of crack width) According to: EN 1992-1-1:2004+AC2:2010 Section 7. com? EurocodeApplied. 2. 2 (3) the effects of non-linear creep should be Jan 1, 1992 · According to EN 1992-1-1 §7. according to EN 1992-1-1 §7. Jan 1, 1992 · Eurocode 2. e. In this calculation the density of reinforcement steel is assumed equal to ρ = 7850 kg/m. ULS Design of steel member (beam/column) with hollow rectangular or hollow square cross-section (RHS, SHS or custom) Ultimate Limit State design of uniform steel member (beam/column) with hollow rectangular section or hollow square section (RHS, SHS or custom) according to EN1993-1-1 for axial force N, shear force V, bending moment The elastic displacement response spectrum SDe ( T) is obtained by direct transformation of the elastic acceleration response spectrum Se ( T) according to the fundamental relation of structural dynamics, as specified in EN1998-1 §3. at distance ≤ l0 / 3 from the lap ends. For a list of concrete classes see Table of Concrete Design Properties. 50 is applicable for variable actions. Members with uniform cross-section, doubly symmetric rolled I Jan 4, 1991 · The reference height for the wind action ze is equal to the upper height of the different wall parts for the windward wall (zone D) and maximum height above ground of the building h for leeward wall (zone E) and sidewalls (zones A, B, C), as specified in EN1991-1-4 §7. EN1993-1-1. 2 (1)P and its value is provided in the National Annex. 2 (3) the effects of non-linear creep should be Jan 1, 1992 · Description: Minimum reinforcement to control cracking of reinforced concrete - Rectangular cross-sections or webs of profiled cross-sections. roofs of structures not enclosed with permanent side walls). Calculation of creep coefficient Intermediate factors. These were developed by the European Committee for Standardization upon the request of the European Commission. A vertical wall back surface corresponds to ψ = 90°. 9516 2 / (0. The total horizontal force, horizontal eccentricity, and base overturning moment are calculated from the force coefficient corresponding to the overall effect of the wind action on the structure. Design of shear connection at the interface between concrete cast at different times. The European Standard EN 10365 has superseded the following older standards: Geometry of IPE profiles: Euronorm 19 What is EurocodeApplied. Shear modulus: G = E / [ 2⋅ (1 + ν) ] = 80769 MPa ≈ 81000 MPa. According to: EN 1998-1:2004 Section 3. The Eurocodes are the ten European standards (EN; harmonised technical rules) specifying how structural design should be conducted within the European Union (EU). Jan 4, 1991 · The wind force Fw corresponding to the overall wind effect on each sloped face of the canopy roof is calculated in accordance with EN1991-1-4 equation 5. 1(1) for intermediate loaded areas A between 1m 2 and 10m 2 the external pressure coefficient c pe may be calculated between the values c pe,1 Jan 1, 1993 · Eurocode 3. The directional and season factors are Design properties of hot finished Square Hollow Section (SHS) for S235 steel class ( γM0 = 1. Direction of the wind θ = 90° corresponds to wind parallel or nearly parallel to the direction of low eave and high eave (i. The values of ag ⋅ S, TC, TD must be provided manually. Jan 1, 1993 · For typical steel profiles (IPE, HEA, HEB, HEM, UB, UC, UBP) the geometric properties of the cross-section are defined in the following standard: EN 10365 - Hot rolled steel channels, I and H sections - Dimensions and masses. The current approach of safety factor calculation applied in the Eurocodes is disclosed here. Load combinations Jan 4, 1991 · Appropriate load factors should be applied for the relevant design situation. 7671 m 2. Added on: 22 October 2023. Elastic displacement response spectrum. The net effect of the wind pressure on the upper and lower surface for zones A, B, C on the roof surface are Jan 4, 1991 · Description: Calculation of peak velocity pressure qp depending on the basic wind velocity from National Annex wind map, and the site distance from shoreline and town boundary. where cf,0 is the force coefficient without free-end flow, ψr is the reduction factor for rounded corners, and ψλ the end effect factor, as calculated above. 2 (3) the effects of non-linear creep should be Jan 1, 1992 · Minimum reinforcement to control cracking. Wind load on signboards (force coefficient) Description: Calculation of wind load action effects on signboards with rectangular surface area. 0 kN/m 3 and 78. In order to calculate the final wind actions on the structure (wind force or wind pressure) the appropriate force coefficient or pressure coefficient depending on the type of structure must be applied, as specified in EN1991-1-4 §5. 9561⋅0. Design properties of hot finished Rectangular Hollow Section (RHS) for S235 steel class ( γ M0 = 1. 000 m = 1000 mm, as specified in EN1992-1-1 §3. 6 fck for the characteristic SLS combination for adverse environment (exposure classes XD, XF, XS) and in the absence of other measures. Eurocode 8 Design earthquake action during construction phase Description: Calculation of the reduced earthquake ground acceleration applicable during the construction phase of the structure as a function of the duration of the construction stage (applicable for any type of structure, not only bridges) Jan 1, 1992 · Concrete Design Properties according to EN1992-1-1 ( γc = 1. The European Standard EN 10365 has superseded the following older standards: Geometry of IPE profiles: Euronorm 19 Eurocode 2 SLS design of I-shaped, T-shaped, and box-shaped reinforced concrete cross-section for stress limitation Description: SLS design of I-shaped, T-shaped, and box-shaped reinforced concrete cross-section for stress limitation (calculation of required reinforcement for given bending moment / axial force, maximum moment resistance for given axial force, or complete M-N interaction Jan 1, 1992 · According to EN 1992-1-1 §7. Axial force & shear resistance. 1(1) for intermediate loaded areas A between 1m 2 and 10m 2 the external pressure coefficient c pe may be calculated between the values c pe,1 Jan 4, 1991 · The basic wind velocity is given as vb = vb,0 ⋅ cdir ⋅ cseason where the fundamental value of basic wind velocity vb,0 is defined in EN1991-1-4 §4. 3 (2) the following modifications are applicable for the value of the concrete modulus of elasticity Ecm: a) for limestone aggregates the value should be reduced by 10%, b) for sandstone aggregates the value should be reduced by 30%, c In total there are 58 EN Eurocode parts distributed in the ten Eurocodes (EN 1990 – 1999). Dynamic earth pressure coefficient for earthquake analysis (Mononobe-Okabe) Smaller values lead to more unfavorable results. 50, fyk = 500 MPa) According to EN1992-1-1 §3. Area of gross cross-section: A = 1. For n isolated reinforcement bars the total weight is: wtot = n ⋅ ρ ⋅ As. The unit weight of steel γ is specified between 77. 25. Jan 1, 1992 · According to EN 1992-1-1 §7. 2 (2)P. Therefore: EurocodeApplied. 1. perpendicular or nearly perpendicular to the slope direction). Box-shaped cross-section can be treated as an equivalent I-shaped cross-section accounting for the total width of webs. The calculated peak velocity pressure q p (z e) is the wind pressure corresponding to the peak wind velocity. Applicable for seismic isolation system with FPS, LRB, HDRB isolators and viscous dampers. Area properties. According to EN1991-1-4 §7. Preliminary analysis of seismic isolation system with the equivalent linear single-degree-of-freedom (SDOF) method. 3 Jan 8, 1993 · Design aid - Table of design properties for individual metric hexagonal bolts including stress area, yield strength, ultimate strength, shear resistance, tensile resistance, interaction between shear and tension, bearing resistance, punching shear resistance. 2 (6) for more information. Description: Calculation of the design response spectrum in terms of spectral acceleration representing the seismic action in the horizontal or vertical direction. EN 10219-2: Cold formed welded structural hollow sections of non-alloy and fine grain steels. 5 (2), §6. For typical Circular Hollow Sections (CHS) the geometric properties of the cross-section are defined in the following standards: EN 10210-2: Hot finished structural hollow sections of non-alloy and fine grain steels. 2 (5)P : SDe ( T) = Se ( T) ⋅ [ T / (2π)] 2. com is a free online service that civil engineers can use to perform structural design calculations according to the latest Eurocodes Jan 1, 1993 · Eurocode 3. Dec 28, 2020 · The safety factor calculation for the permanent and the variable load in the Eurocodes is based on the independent, i. The following intermediate factors and coefficients are calculated: The notional size h 0 of the cross-section is calculated as h 0 = 2A c / u = 2⋅1. 6 (2). Therefore the dynamic earth pressure coefficient for passive states according to Mononobe-Okabe method is calculated as KPE = 2. The European Standard EN 10365 has superseded the following older standards: Geometry of IPE profiles: Euronorm 19 Jan 4, 1991 · Direction of the wind θ = 0° corresponds to wind parallel or nearly parallel to roof slope direction from low eave to high eave. qx fl ud va di ly rm dy tp bs